EV charging Controller AC-EV-CC-AC1-M3-CBC-RCM-ETH-3G (OCPP) - 1018702

EV charging Controller AC-EV-CC-AC1-M3-CBC-RCM-ETH-3G (OCPP) - 1018702

Product rating: 5/5 (1x)

Your rating:

NEW

Charge control unit for charging AC electric vehicles according to IEC 61851-1, including DC fault current monitoring, automatic plug locking in case of power failure, interface for meter and RFID reader. Configuration and control via an Ethernet interface or mobile network interface (OCPP).

713,90 € incl. VAT

590 €

Availability: In stock

Producer: Phoenix Contact

Module 3 for charging electric vehicles according to IEC 61851-1 for B and C charging with integrated DC fault current monitoring, Ethernet communication interface and 3G mobile modem.

Product definition

  • Product Type: AC Charge Controller for Private and Industrial Applications (EU / CN)
  • Standards / Regulations: IEC 61851-1
  • Charging mode: Mode 3, Case B + C 
  • Number of supported charging points: 1
  • Enable blocking when a network failure: Integrated blocker actuator release function to disconnect the infrastructure charging connector and infrastructure charging socket
  • Conformity: CE 

Dimensions

  • Height: 90 mm
  • Width: 162 mm
  • Depth: 61.00 mm

Device power supply

  • Supply voltage: 230 V
  • Supply voltage range: 100 - 240 V AC (rated voltage range)
  • Power consumption: <3 watts (idle)
  • Power consumption: <10 W (maximum)
  • Frequency range: 50 - 60 Hz

Range of differential current measurement

  • Rated frequency fn: ≤ 2000 Hz
  • Rated differential current: ± 300 mA
  • Charge current IΔn: 30 mA (AC), 6 mA (DC)
  • Start time at IΔn: <180 ms
  • Rated current In: 32 A (three-phase, 4 x 6 mm²), 48 A (single phase)
  • Response time at 2 x IΔn: <70 ms
  • Starting time at 5xIΔn: <20 ms

Range of differential current measurement

  • Rated frequency fn: ≤ 2000 Hz
  • Rated differential current: ± 300 mA
  • Charge current IΔn: 30 mA (AC), 6 mA (DC)
  • Start time at IΔn: <180 ms
  • Rated current In 32 A: (three-phase, 4 x 6 mm²), 48 A (single phase)
  • Response time at 2 x IΔn: <70 ms
  • Starting time at 5xIΔn: <20 ms

Switching outputs

  • Charging contactor control: Relay output C1.2
  • Switching power minimum: 4000 VA
  • Switching voltage max.: 250 V AC (External power supply)
  • Maximum switching current: 16 A
  • Locking Actuator Control: Motor Switch Output
  • Switching voltage max.: 12 V (Internal power supply)
  • Maximum switching current: 1 A (maximum)

Digital outputs

  • Control of other functions: 4 digital outputs
  • Connection technique: Screw connection
  • Maximum output voltage: 30 V
  • Maximum output current: 0.2 A (Total current for all outputs, internal power supply)
  • Maximum output current per channel: 0.6 A (one output, external power supply)

Inputs

  • Number of digital inputs: 5
  • Input description: Digital input
  • Rated current IN: ≤ 4 mA
  • Input nominal voltage UN: 12 V
  • Input Voltage Range U1: 0 - 3 V (Off)
  • Input voltage range U2: 9 - 15 V (On)

Data interfaces RS-485

  • Number of interfaces: 1 (for meter and RFID reader)
  • Bus system: RS-485
  • Connection type: Screw connection
  • Number of supported participants: 2
  • Transfer rate: 4.8 - 115.2 kBit / s (setting option)
  • Supported Protocols: Modbus / RTU (Master) 

Ethernet data interfaces

  • Number of interfaces: 1
  • Connection type: RJ45 socket
  • Transfer rate: 10/100 MBit / s
  • Transfer length: 100 m
  • Supported protocols: Modbus / TCP 

Wireless Interfaces

  • Interface Description: HSPA / GSM / SPRS / EDGE Mobile Data Interface for Communication with Superior                                  Control Systems via OCPP 1.6J
  • Frequency: 900 MHz (HSPA)

                           2100 MHz (HSPA)

                           850 MHz (GSM / GPRS / EDGE)

                           900 MHz (GSM / GPRS / EDGE)

                           1800 MHz (GSM / GPRS / EDGE)

                           1900 MHz (GSM / GPRS / EDGE)

  • Impedance: 50 Ω
  • Transmit power: 2 W  (GSM 850 (Class 4))

                                  2 W (GSM 950 (Class 4))

                                  1 W (GSM 1800 (Class 1))

                                  1 W (GSM 1900 (Class 1))

                                  + 24 dBm (UMTS / HSPA (Class 3))

  • Antenna connection: 1, SMA (plug)
  • SIM card: Micro SIM
  • Supported OCPP: 1.6J protocols

Ambient conditions

  • Ambient temperature (operation): -25 ° C + 60 ° C
  • Ambient temperature (storage / transport): -40 ° C + 85 ° C
  • Max. altitude: <2000 m
  • Permissible air humidity (operation): 30% - 95% (no condensation)
  • Degree of protection: IP20
  • Pollution degree: 2 IEC 60664-1
  • Overvoltage category: II

Connection data

  • Connection type: Screw connection
  • Conductor cross section: 0.2 - 2.5 mm²
  • Conductor cross section solid: 0.2 - 4 mm²
  • AWG line cross section: 24 - 12
  • Connection type: Screw connection
  • Conductor cross section: 0.2 - 1 mm²
  • Conductor cross section solid: 0.14 - 1.5 mm²
  • AWG line cross section: 26 - 16 

Electromagnetic Compatibility Data

  • Electromagnetic Compatibility: Compliance with the 2014/30 / EU Electromagnetic Compatibility Directive
  • Spurious radiation: EN 61000-6-3 
  • Interference immunity: EN 61000-6-2
  • Low Voltage Directive: Compliance with NSR 2014/35 / EU
  • Case: DIN 43880

 

New comment

* (Required)

Login

This website uses cookies. More info